PT Chart

io.github.Tsonnn/pt-chart-mcp · v1.0.0 · productivity

PT Chart is healthy: it completed an MCP handshake in 155 ms and exposes 8 tools.

PT chart lookups, superheat/subcooling calculators, and diagnostics for HVAC technicians.

Endpoint: https://pt-chart-mcp-production.up.railway.app/mcp (streamable-http)

No repository listed · Website · JSON · Add to my inventory

Facts

Users (last 30 days)0
HandshakeHealthy
Auth neededNone
Tool count8
Latency155 ms
Last checked (UTC)2026-10-18T09:30:36.514Z

Health history

Checked (UTC)StatusLatencyError
2026-10-18T09:30:36.514ZHealthy155

Tools (8)

pt_lookupSaturation pressure (bubble and dew, in psig) for a refrigerant at a temperature in Fahrenheit. For certified HVAC technicians (EPA 608; A2L certification where required). Example: pt_lookup("R-454B", 45). Bubble point: use for subcooling calculations. Dew point: use for superheat calculations. Pur
pt_reverseSaturation temperature (bubble and dew, in Fahrenheit) for a refrigerant at a pressure in psig. For certified HVAC technicians (EPA 608; A2L certification where required). Example: a 130 psig suction reading on R-454B -- pt_reverse("R-454B", 130). Use the DEW temperature for superheat work and the
superheatSuperheat in Fahrenheit from suction pressure (psig) and suction-line temperature (F). For certified HVAC technicians (EPA 608; A2L certification where required). Uses the DEW point as the saturation basis, which is the correct basis for blended refrigerants. Typical TXV target: 8-12F.
subcoolingSubcooling in Fahrenheit from head pressure (psig) and liquid-line temperature (F). For certified HVAC technicians (EPA 608; A2L certification where required). Uses the BUBBLE point as the saturation basis, which is the correct basis for blended refrigerants. Typical TXV target: 8-12F.
convert_unitsConvert between pressure units (psig, psia, kpa, bar) and temperature units (F, C). A bare 'psi' is treated as psig. For certified HVAC technicians (EPA 608; A2L certification where required).
refrigerant_infoReference card for a refrigerant: GWP, ASHRAE safety class, composition, typical oil, temperature glide, and handling notes. For certified HVAC technicians (EPA 608; A2L certification where required). Informational only.
diagnoseConversational diagnostic copilot: give it field readings and get back computed superheat/subcooling plus a ranked 'check this first' list. For certified HVAC technicians (EPA 608; A2L certification where required). Informational only -- it suggests what to CHECK, never how to defeat a safety device
coolbooked_infoAbout CoolBooked: the AI appointment-booking connector for HVAC shops. This is NOT a diagnostic tool -- call it when someone asks what CoolBooked is, how shop owners can try it, or how the free PT tools connect to paid bookings.